Safety and Compliance

DRI LIGHTNING® CONDUCTIVE CLOTH

 Always use caution when using the Dri Lightning® Testing Kit. 

Industry Safety standards require that you have been trained to use any kit when testing.   Insulation mats for AC or DC testing.  It is suggested that each liner be tested twice a year, however industry standards require yearly testing.

Bullet  No high voltage rigging into bucket liner filled with water
Bullet  No water with Dri Lightning
Bullet #6 bare copper static/drain wire used for both ac and dc testing
Bullet No sectional testing – conducted self adhesive mats fill any voids

Dielectric Testing Standards

HKH Dielectric, LLC. Offers a complete process and kit to do Dielectric Testing for your company.  With safety always being our first concern, we are ready to get you started with our easy kit and process.

Ensure that you are in accordance with OSHA and ANSI Standards:

Compliance   OSHA 1910.67 (c) (3) Standard:
“Electrical tests.” Electrical tests shall be made in conformance with the requirements of ANSI A92.2 – 2001, Section 5.  However, equivalent DC voltage tests may be used in lieu of the AC voltage test specified in A92.2 – 2001.  DC  voltage tests which are approved by the equipment manufacturer or equivalent entity shall be considered an equivalent test for the purpose of this paragraph (c) (3)

ANSI A9.2-2001 Standard:

5.3 Electrical Tests For Insulating Aerial Devices
…5.3.2 Qualification Test

Each insulating aerial device shall be tested in accordance with Section 5.4.2 to insure compliance with the Electrical Qualification requirements as appropriate.    If the aerial device is altered or modified by the installer after the Qualification Test is performed, the original Qualification Test is not valid.

To satisfy OSHA requirements Single and Double Buckets units are to be dielectrically tested annually.  Let Dri Lightning® show you how to save money, time and water while keeping you in compliance.  We realize that Safety and Compliance are top priorities for our customers. 


The conductive cloth used for DRI LIGHTNING® sock sets is not a “Hazardous waste” as that term is defined in 40 CFR 261, “Identification and Listing of Hazardous Waste.

Disposal       

Dispose of waste by recovery of metals, incineration, sanitary landfill or other methods in accordance with all applicable local, state and federal laws and regulations.

DRI LIGHTNING® is the only Patented WATERLESS testing method that meets ANSI/OSHA standards. 

DRI LIGHTNING® is the only Patented WATERLESS testing method that meets ANSI/OSHA standards.  DRI LIGHTNING® is the only method that leaves a distinctive mark on the liner exactly where insulation has broken down.  Manufactured in the USA to the highest standards.  Meeting ISO 9001 and RoHS standards.

No or little possibility of flashover eliminating false positive defective liners. (No more guessing on your employee’s safety).  DRI LIGHTING® leaves you proof.

No more retesting because someone says or thinks “but that’s a new liner”.  BE SAFE, test with the dry testing method that shows the proof.  Our method is used with either AC or DC equipment.

Conductive Mats

With every DRI LIGHTNING® kit, comes 6 conductive self adhesive backed 12” x 12” mats, that are used in (2) different situations; (1) for insets of steps and booms as well as other odd shaped liners, and (2) for minor repairs of the conductive sock set material when arching holes thru the material become larger than 3 – 5 cm.

NOTE:  Conductive mats are not to be used as a repair to any defective seems.  These are covered by DRI LIGHTNING®’s limited life time warrantee conditions. 

 

Limited Lifetime Warranty

Dri Lightning® (DL) warrants the products included in our kits, which include duffel bag, brief bag, expander rods, hub assembly pieces, rod couplings, elastic band, netting Velcro bands, expander sleeves and the conductive adhesive on patch mats for a period of one (1) year against any manufacturing defects under normal use and service conditions.  DL will replace or repair, at its option, any portion or parts in whole.  DL does not warranty against any material used improperly on liners of varying sizes not designated by DL for that liner, any improper washing, drying or storage of DL metallic conductive cloth, elastic bands, netting or Velcro bands.

DL conductive metallic sleeves are guaranteed against conductivity failure on any part of sleeves under normal conditions and strict adherence to DL’s procedures in the instruction manual.  DL shall upon their review determine and have the option of claim denied after receiving said material to determine defectiveness.