Safety
and Compliance
DRI LIGHTNING® CONDUCTIVE CLOTH
Always
use caution when using the Dri Lightning® Testing Kit.
Industry
|
|
No high voltage rigging into bucket liner filled with water |
|
|
No water with Dri Lightning |
|
|
#6 bare copper static/drain wire used for both
ac and dc testing |
|
|
No sectional testing – conducted self adhesive
mats fill any voids |
Dielectric Testing Standards
HKH Dielectric, LLC. Offers a complete process and kit to do
Dielectric Testing for your company. With safety always being our
first concern, we are ready to get you started with our easy kit and
process.
Ensure that you are in accordance
with OSHA and ANSI Standards:
Compliance
OSHA 1910.67 (c) (3) Standard:
“Electrical tests.” Electrical tests shall be made in conformance with
the requirements of ANSI A92.2 – 2001, Section 5. However, equivalent
DC voltage tests may be used in lieu of the AC voltage test specified in
A92.2 – 2001. DC voltage tests which are approved by the
equipment manufacturer or equivalent entity shall be considered an
equivalent test for the purpose of this paragraph (c) (3)
ANSI A9.2-2001 Standard:
5.3 Electrical Tests For Insulating Aerial Devices
…5.3.2 Qualification Test
Each insulating aerial device shall be tested in accordance with Section
5.4.2 to insure compliance with the Electrical Qualification requirements as
appropriate.
If the aerial device is altered or modified by the installer after the
Qualification Test is performed, the original Qualification Test is not
valid.
To satisfy OSHA requirements Single and Double Buckets units are to
be dielectrically tested annually. Let Dri Lightning® show you how to
save money, time and water while keeping you in compliance. We realize that
Safety and Compliance are top priorities for our customers.
The conductive cloth used for DRI LIGHTNING® sock sets is not a “Hazardous
waste” as that term is defined in 40 CFR 261, “Identification and Listing of
Hazardous Waste.
Disposal
Dispose of waste by recovery of metals, incineration, sanitary landfill or other methods in accordance with all applicable local, state and federal laws and regulations.
DRI LIGHTNING® is the only
Patented WATERLESS testing method that meets ANSI/OSHA standards.
DRI LIGHTNING® is the only Patented
WATERLESS testing method that meets ANSI/OSHA standards.
DRI LIGHTNING® is the only method that leaves a distinctive mark on
the liner exactly where insulation has broken down.
Manufactured in the USA to the highest standards.
Meeting ISO 9001 and RoHS standards.
No or little possibility of flashover
eliminating false positive defective liners. (No more guessing on your
employee’s safety). DRI
LIGHTING® leaves you proof.
No more retesting because someone says or thinks “but that’s a new liner”.
BE SAFE, test with the dry testing method that shows the proof.
Our method is used with either AC or DC equipment.
Conductive Mats
With every DRI LIGHTNING® kit, comes 6 conductive self adhesive backed 12” x 12”
NOTE: Conductive mats are not to be used as a repair to any defective seems. These
Limited Lifetime Warranty
Dri Lightning® (DL)
warrants the products included in our kits, which include duffel bag,
brief bag, expander rods, hub assembly pieces, rod couplings, elastic
band, netting Velcro bands, expander sleeves and the conductive adhesive
on patch mats for a period of one (1) year against any manufacturing
defects under normal use and service conditions.
DL will replace or repair, at its option, any portion or parts in
whole. DL does not warranty
against any material used improperly on liners of varying sizes not
designated by DL for that liner, any improper washing, drying or storage
of DL metallic conductive cloth, elastic bands, netting or Velcro bands.
DL conductive
metallic sleeves are guaranteed against conductivity failure on any part
of sleeves under normal conditions and strict adherence to DL’s
procedures in the instruction manual.
DL shall upon their review determine and have the option
of claim denied after receiving said material to determine
defectiveness.
Member Since 2009